Description
KG-F series User Manual:
//68.168.132.244/KG-F_EN_manual.pdf
Android phone App link:
//68.168.132.244/app/KG.apk
IOS mobile App link: Search Apple Store for KG Series
KG-F series firmware upgrade log:
//68.168.132.244/KG/KG-F_DFU_log_20220410_EN.pdf
Quick Installation Video:
//www.youtube.com/watch?v=C5G0iR-kUr8
Wiring video :
//www.youtube.com/watch?v=GMs71vDMPnM
Operation video:
//www.youtube.com/watch?v=rO4zFgKY_NA&t
Mobile APP control video:
//www.youtube.com/watch?v=1ixb0Ddaf4g&t
KG-F series color screen wireless bluetooth battery coulomb meter is a professional instrument for monitoring battery power, and it can also monitor the voltage, current, power, ambient temperature, and energy of the battery during charging and discharging.Real-time display of how long the battery can be fully charged and how long the remaining battery power can be used. The measuring current range of KG110F is 0-100A, the measuring current range of KG140F is 0-400A, and the measuring current range of KG160F is 0-600A. 0-120V lead-acid batteries, lithium batteries, iron-lithium batteries and all other batteries can be used.
►2.4-inch color screen, larger and clearer fonts, beautiful appearance;
►Automatically identify the current in both charging and discharging directions;
►Using current x working time to calculate the capacity of charging and discharging is more accurate than calculating the remaining capacity by voltage;
►The mobile APP can connect to the meter through wireless Bluetooth to view data and set parameters;
►The mobile phone APP can upgrade the firmware of the measurement module;
►The mobile APP can view the real-time curve and historical curve of voltage and current, and support historical data export;
►The shunt and the screws are made of pure copper material, and the power consumption in standby mode is very low;
►After configuring the relay, it can realize over-voltage protection, under-voltage protection, over-current protection, over-temperature protection, and over-power protection the delivery list does not include relays
►The parameters of voltage, current and temperature can be calibrated by themselves;
►The display and measurement module are connected through a 3 meter telephone line, and the maximum length can be extended to 30 meters, which is more convenient for installation;
Model
KG110F
KG140F
KG160F
Sampling method
Shunt
Shunt
Shunt
Voltage measurement rangeExternal power supply
0-
120
V
0-
120
V
0-
120
V
Voltage measurement
rangeSelf-powered
10-80V
10-80V
10-80V
Voltage resolution
0.01V
0.01V
0.01V
Current measurement range
0~100A
0~400A
0~600A
Current resolution
0.01A
0.1A
0.1A
Relay
optional
Temperature measurement range
-20-120℃
Capacity display range
0~100
Power measurement range
0~
72
KW
Power resolution
0.01W
AH measurement range
0~9999.99AH
Capacity resolution
0.001AH
Watt-hour measurement range
0~9999.99kWH
Watt-hour accuracy
0.001WH
Time measurement range
0~999:59:59S
Time resolution
1second
Bluetooth communication distance
10m
Voltage accuracy
±1+2 characters
Current accuracy
±1+5 characters
Sampling rate
time
/second
Measuring module
power consumption
About 0.4W
Display module power consumption
About 0.5W
Over power protection
0-99999.99W
Negative overcurrent protection
0~50A/100A/400A/600A
Forward overcurrent protection
0~50A/100A/400A/600A
Overvoltage protection
0~1
2
0V/600V
Undervoltage protection
0~1
20
V/600V
External over temperature protection
0-120℃
Protection recovery time
0-99s
Enter standby time
0-60s
Delay time setting
0-99S
Mailing address
There are 99 P01-P99, P00 is the broadcast address
The interface cool
function is powerful
to use mobile app,
can operate remotely,
support data recording
and export, convenient
and quick.
Mobile app supports
curve display, real-time
curve and history curve
of voltage and current,
and historical data
export.
►Over voltage, under voltage, over current, over power and external
over temperature protection can be set,When the value is not in the
range of protection value,the output state of the meter is turned off
cooperation is required The relay is used to prevent the electrical
equipment from being damaged.
►The protection recovery time and delay time can be set, which is
suitable for various occasions.
OVP
Over Voltage Protection
OTP
Over Temperature Protection
LVP
Low Voltage Protection
OPP
Over Power Protection
OCP
Over Current Protection
NCP
Negative Over Current Protection
Suitable for all batteries within the voltage measurement rangeand the actual capacity value of the battery can be set.
1> Display Module x 1
5> 3P Terminal x 1
2> Measuring Module x
6> 3m Communication Cable x 1
3> Sampler x 1
7> 3P Connection Cable x 1
4> Temperature Sensor x 1
8> 4P Connection Cable x 1
1. Added a low-capacity reminder to the mobile APP;
2. The low temperature protection is added to the mobile APP this function requires the installation of a relay;
3. The temperature can be switched to display Fahrenheit or Celsius;
4. The accumulated power kW.h only calculates the power consumed during charging;
5. Cumulative capacity Ah only calculates the capacity released during discharge;
6. The scale range of the voltage and current instrument panel in the mobile phone APP can be set freely, and the scale value of the voltage and current curve also changes accordingly;
7. Four extended functions have been added to the mobile APP: full voltage, power deficit, full current, and detection time. For example, for a 12V 400Ah lead-acid battery, set the full voltage to 14.4V and the full current to 2 Indicates that the full current is 400 x 0.02=8A, and the detection time is set to 2 minutes, which means that when the voltage is higher than 14.4V, the charging current is lower than 8A, and the duration exceeds 2 minutes during the charging process, the percentage of remaining capacity will be automatically adjusted is 100;
Set the power-loss voltage to 10.5V and the detection time to 2 minutes, which means that the percentage of remaining capacity will be automatically adjusted to 0 after the voltage is lower than 10.5V during the discharge process and the duration exceeds 2 minutes if you feel that the power-loss voltage is this If the function is not very practical, you can set the full voltage, full current, and detection time without setting the voltage deficit;